Nyquista Team

When conversations, laughter and the evening television from the neighbouring apartment can be heard clearly through the wall, it is difficult to rest peacefully in your own home. In older prefabricated concrete panel blocks, and in some new developments, thin party walls or construction defects cause the wall to act almost like a loudspeaker membrane. As the problem grows, many people turn to the quickest solutions available at DIY stores: cork panels, polyurethane foams, thin upholstered panels or ordinary polystyrene.
Unfortunately, intuition is often misleading in building acoustics. Materials that feel soft to the touch and are associated with quiet do almost nothing to block sound passing through the wall. To understand how to restore peace and quiet in your apartment without unnecessary expense or loss of valuable floor space, it is worth separating building physics from popular myths.
Why won't acoustic foam and cork soundproof a party wall?
Acoustic foam, cork and thin felt are designed to absorb reverberation inside a room (the αw parameter and RT60 reverberation time), but they do not block sound waves travelling from the neighbouring unit (sound insulation Rw and R'w). Stopping noise from behind a wall requires substantial mass and elastic decoupling of layers, which lightweight porous materials physically cannot provide.
Confusing sound absorption with sound insulation is the most common reason for disappointment after a DIY renovation. Covering a wall with pyramid foam or upholstered panels will eliminate echo in your own living room. However, your neighbour's conversations and television will remain audible at almost the same volume. We discuss this difference in detail in the article sound-absorbing vs soundproofing panels.
Gluing ordinary expanded polystyrene (EPS) or a thin cork mat to the wall produces an even worse result. Polystyrene is a rigid, closed-cell material that provides excellent thermal insulation, but acoustically it can act as a resonance box. In the frequency range of human speech, such cladding can actually reduce the wall's sound insulation by 2–4 dB, making voices from behind the wall clearer than before the renovation.
Effective wall acoustic insulation is based on two laws of physics:
The mass law: the heavier and more airtight the partition, the harder it is for a sound wave to set it vibrating.
The mass–spring–mass system: between the existing wall (the first mass) and a heavy cladding layer (the second mass), there must be an elastic damping material (the spring) that absorbs vibration energy and prevents it from being transmitted into the room.
Comparison of wall soundproofing methods - thickness, effectiveness and risk of errors
The effectiveness of wall soundproofing depends on the system's design, its thickness and its susceptibility to installation errors. Lightweight cladding delivers no measurable effect, a traditional stud-framed independent wall lining requires 10–15 cm of space and highly precise installation, while ready-made systems without a substructure achieve high sound insulation with minimal loss of room space.
Soundproofing method | Build-up thickness | Actual effectiveness | Risk of errors and limitations |
Acoustic foam, cork, polystyrene | 10–40 mm | No improvement in sound insulation (polystyrene may reduce it by 2–4 dB in the speech range) | Often mistaken for insulation; foam only reduces reverberation in the room, and cork does not stop sound from neighbours |
Conventional plasterboard wall lining on a stud frame with mineral wool | 100–150 mm | Good (+8 to +15 dB), provided the studs are fully decoupled and double-boarded | High risk of acoustic bridges (rigid screws into the wall, no acoustic tapes), significant loss of floor space |
System without substructure | approx. 35–40 mm (with plasterboard) | Significant improvement in sound insulation in a lightweight build-up while maintaining minimal thickness | Requires a level substrate and installation exclusively with a solvent-free elastic adhesive (no screws permitted) |
Five-layer system | 63 mm | Very high: increases the sound insulation of a 12 cm brick wall from 40 dB to Rw ≥ 62 dB | Requires continuity of layers, sealed perimeter expansion joints and relocation of sockets to surface-mounted or insulated boxes |
A traditional plasterboard wall lining on a metal frame can perform well, but it has two significant drawbacks in apartment blocks. First, in a small bedroom or narrow living room, it takes up 12–15 cm of space along the entire length of the room. Second, just a few rigid hangers screwed directly to the wall without vibration isolators are enough to create acoustic bridges, through which vibrations bypass the mineral wool and negate most of the effect.
How does a floating system without a substructure work (SilenceMat and NyquiFix Pro)?
Floating systems without a metal frame eliminate acoustic bridges by replacing rigid anchors and profiles with a continuous layer of elastic anti-vibration underlay and heavy barrier boards. This arrangement implements the mass–spring–mass principle in a much thinner cross-section. The 63 mm five-layer NyquiFix Pro system increases the sound insulation of a 12 cm brick wall from 40 dB to Rw ≥ 62 dB.
A difference of more than 20 dB is enormous to the human ear. The decibel scale is logarithmic, which means that a 10 dB reduction in sound level is subjectively perceived as halving the noise. A jump from 40 dB to 62 dB therefore corresponds to more than a fourfold reduction in perceived loudness of sounds coming through the wall. Normal conversation or television sound from the neighbouring apartment falls below the threshold of audibility against the typical background noise of a home.
The effectiveness of modern systems without a substructure results from a carefully designed sequence of materials of different densities:
Elimination of the metal frame: the absence of profiles screwed to the wall removes the rigid contact points through which sound travels most easily.
Resilient anti-vibration layer: in solutions such as the SilenceMat insulation mat a high-density elastic composite absorbs vibrations from the structural wall and dissipates their energy, acting as the “spring” that separates the finishing layer from the wall.
Multi-layer high-mass barrier: the five-layer NyquiFix Pro system combines a heavy anti-vibration underlay, dense damping layers and a special Sound-Block acoustic board with increased surface mass. Each boundary between layers of different density reflects and attenuates a further portion of the sound wave's energy, including the harder-to-stop low-frequency speech and bass from speakers.
Space savings and simple finishing: a total thickness of 63 mm means that in a room 3 metres wide the loss of floor space is almost imperceptible, and the top layer is skimmed and painted just like a standard plasterboard wall.
4 installation errors that can ruin the soundproofing effect
Even the best acoustic material will lose much of its performance if gaps or rigid connections to the building structure are created during installation. Sound behaves much like water and exploits every weak point in a partition. Avoiding the four most common installation errors ensures that the system's declared sound insulation is maintained in the finished room.
Screwing insulation layers in place instead of using elastic adhesive. In systems without a substructure, such as
SilenceMat, only solvent-free elastic mounting adhesive is used for fixing. Piercing the insulation layers with a metal screw or wall anchor creates a rigid acoustic bridge. A dozen or so such points can reduce the effectiveness of the entire wall by several decibels.No perimeter expansion joints. If the new build-up is in rigid contact with the floor, ceiling and side walls, vibrations from the building structure are transmitted into it laterally. Elastic expansion tape must be applied around the entire perimeter, and after finishing, the gap should be filled with a permanently elastic acoustic sealant instead of hard filler plaster.
Electrical boxes penetrating the insulation. Sockets and switches built into a party wall are among the weakest acoustic points in an apartment block (often the neighbour's socket is located in the same spot on the other side). Cutting openings for boxes in the new insulation layer creates an acoustic “hole”. Existing boxes in the wall must be tightly sealed with acoustic compound or mortar, and new sockets should be installed as surface-mounted units or in special acoustic enclosures, maintaining continuous insulation behind the box.
Ignoring flanking transmission through the ceiling and perpendicular walls. In prefabricated concrete panel buildings or those built with lightweight blocks, sound from behind the wall also travels laterally, through the shared floor slab, the floor screed and partition walls adjoining the neighbour's wall. We describe these paths in more detail in the article noisy neighbours – how sound travels between apartments. Soundproofing the party wall alone eliminates the main path for airborne sound, but where flanking transmission is very strong, it is advisable to assess the adjoining walls before installation as well.
Frequently Asked Questions (FAQ)
How many centimetres of room space does effective wall soundproofing take up?
An effective multi-layer system without a metal frame, such as NyquiFix Pro, is 63 mm (6.3 cm) thick, including a finishing board ready for skimming and painting. By comparison, a conventional plasterboard wall lining on a decoupled frame with mineral wool offering similar performance typically takes up 10 to 15 cm of room depth.
Is soundproofing one wall enough if I can hear footsteps from above?
No. Footsteps, chairs being moved and stomping are impact (structure-borne) sounds that travel through the rigid structure of the floor slab and load-bearing walls down into the entire room. Insulating one wall effectively reduces conversations, shouting and television from behind that particular partition (airborne sounds). To genuinely reduce footstep noise from above, the most effective solution is to install an acoustic underlay beneath the floor of the upstairs neighbour, or to build a comprehensive acoustic ceiling on vibration-isolating hangers in your own apartment, combined with decoupling of the side walls.
Can the insulation system be installed on a finished, painted wall?
Yes, provided the wall is level, dry and load-bearing. Peeling paint, wallpaper and poorly bonded skim coats must be removed from the substrate, and the surface then primed in accordance with the adhesive's technical data sheet. In bonded systems such as SilenceMat, it is essential to use a suitable solvent-free elastic adhesive that does not damage the material's structure or create a rigid bond.
When is it worth ordering a sound insulation measurement of the partition first?
It is advisable to commission an acoustic measurement of your apartment before renovation in two situations. First, when the noise is disruptive but you are not sure whether it comes mainly through one wall or is transmitted through the ceiling, ventilation shafts or side walls. Second, when you live in a new building still under the developer's warranty and suspect that the partition does not meet the minimum requirements of the Polish standard PN-B-02151-3 (the measurement report then serves as the basis for a warranty claim). In such cases, it is worth using our acoustic measurement services or obtaining support through our acoustic insulation and vibration isolation services.
Bibliography and sources
Standards and building regulations
PN-B-02151-3:2015-10 – Building acoustics. Protection against noise in buildings. Part 3: Requirements for sound insulation of partitions in buildings and building elements (minimum sound insulation requirements for party walls in multi-family buildings).
Regulation of the Minister of Infrastructure of 12 April 2002 on the technical conditions to be met by buildings and their location (consolidated text, Journal of Laws 2022, item 1225) – Section IX: protection against noise and vibration in residential buildings.
ISO 10848-2:2017 (PN-EN ISO 10848-2) – Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms (the phenomenon of flanking sound transmission between adjoining rooms and the methodology for its assessment).
ISO 11654:1997 (PN-EN ISO 11654) – Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (classification of sound-absorbing materials as distinct from soundproofing barriers).
PN-B-02151-4:2015-06 – Building acoustics. Protection against noise in buildings. Part 4: Requirements for reverberation conditions and speech intelligibility in rooms and guidelines for testing.
See also